T-52
C0602
C0605
Step
Check
Result
Action
1
Scanner moves as moved manually.
NO
Correct drive coupling.
Rewind cables.
2
Connector on SCP Board is connected prop-
erly: PJ3IC on PWB-IC.
NO
Connect.
3
Scanner Motor turns when the Start key is
pressed.
NO
Correct drive coupling.
Change motor or SCP
Board.
4
Connector on Image Processing Board is con-
nected properly: PJ306B on PWB-B.
NO
Connect.
5
I/O check for Scanner Reference Position Sen-
sor
YES
Change Image Process-
ing Board.
NO
Correct actuator. Change
sensor.
Step
Check
Result
Action
1
Scanner moves as moved manually.
NO
Correct drive coupling.
Rewind cables.
2
Connector on Image Processing Board is con-
nected properly: PJ306B on PWB-B.
NO
Connect.
3
Light Blocking Plate is installed properly.
NO
Correct.
4
I/O check for Scanner Reference Position Sen-
sor
YES
Change Image Process-
ing Board.
NO
Correct actuator.
Change sensor.