D-47
(7)
Cleaning of the AIDC Sensor Board
(8)
Cleaning of the PC Drum Paper Separator Fingers
(9)
Removal of the Toner Antispill Seal
3. Turning the Bucket Roller, pour fresh developer
evenly into the chamber.
NOTES
• Shake the packet of developer well before opening
it.
• When the developer has been replaced, clear the
counts of “Developer 1” and “Developer 2” of “PM” of
“Counter” available from the Tech. Rep. mode and
run the F8 ATDC Sensor operation.
☞
D-81
1134D051AA
1. Remove the PC Drum.
2. Using a brush or a soft cloth dampened with alco-
hol, clean the AIDC Sensor Board.
4002D136AA
1. Remove the PC Drum.
2. Using a brush or a soft cloth dampened with alco-
hol, clean the PC Drum Paper Separator Fingers.
NOTE
During the cleaning procedure, use care not to
scratch, bend, or otherwise damage the tips of the PC
Drum Paper Separator Fingers. Be also careful not to
get hurt with the tips.
4002D137AA
1. Remove the PC Drum Paper Separator Fingers
Assy.
2. Remove two screws and the Toner Antispill Plate
and Toner Antispill Seal.
4002D138AB
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......