T-49
C0500, C0510
Step
Check
Result
Action
1
Upper Fusing Roller Heater Lamp turns ON
when the Power Switch is turned ON.
YES
Correct thermistor for
mounting position and/or
clean.
2
Lower Fusing Roller Heater Lamp turns ON
when the malfunction is reset with the surface
temperature of Lower Fusing Roller Heater
Lamp is 140°C or less as indicated on “Level
History” under the Tech. Rep. mode.
NO
Check step 7 and onward.
3
Upper and Lower Fusing Roller Thermistors
are installed properly.
NO
Reinstall.
4
Upper and Lower Fusing Roller Thermistors
are dirty.
NO
Clean.
5
Upper Fusing Roller Thermistor operation: the
resistance across CN217-2 and 3 on the Fus-
ing Unit end is infinity with CN217 (4P) discon-
nected.
YES
Change Upper Fusing
Roller Thermistor.
6
Lower Fusing Roller Thermistor operation: the
resistance across CN218-2 and 3 on the Fus-
ing Unit end is infinity with CN218 (4P) discon-
nected.
YES
Change Lower Fusing
Roller Thermistor.
7
Upper Fusing Roller Thermostat and Upper
Fusing Roller Heater Lamp continuity: there is
continuity across CN11-1 and 8 with CN11
(16P) disconnected.
NO
Change thermostat and
heater lamp.
8
Lower Fusing Roller Heater Lamp continuity:
there is continuity across CN11-9 and 16 with
CN11 (16P) disconnected.
NO
Change heater lamp.
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......