D-92
If the loop length falls outside the specified range, perform the following adjustment steps.
4. Call the Adjust mode to the screen.
5. Touch [Printer].
6. Touch [Loop Adjustment].
7. Touch [Drawer].
Setting Instructions
If the loop length is longer than the specifications, decrease the setting value.
If the loop length is shorter than the specifications, increase the setting value.
10. Touch [END] to validate the setting value.
11. Go back to the Basic screen.
12. Press the Start key and check for the loop length again.
13. If the loop length falls outside the specified range, change the setting value and make a
check again.
14. Place a sheet of paper on the Multi Bypass Tray.
15. Following the same procedures, make the loop adjustment for the Multi Bypass Tray.
8. Press the Clear key to clear the current
setting value.
4002D510CB
Use to clear the
setting value.
Use to enter the
setting value.
Use to change the
+ or - sign.
4
7
5
8
0
3
6
9
C
9. Use the 10-key pad to change the setting
value.
NOTE
Use the Access key to select the sign of
+ or -.
4002D514CB
Setting Value