T-65
(19) C0F24: AIDC Sensor contamination correction failure
C0F24
Relevant Electrical Parts
AIDC Sensor Board (PWB-G)
Master Board (PWB-A)
Step
Check
Result
Action
1
PJ7A, CN10, and CN41 are plugged securely
into Master Board.
NO
Plug them in securely.
2
Photosensor/LED of the AIDC Sensor are con-
taminated.
YES
Clean.
NO
Change AIDC Sensor
Board.
Change Master Board.
1
1
24
24
12
12
11
11
10
10
CN10
3
2
1
1
2
3
CN41
PWB-A
PWB-G
AIDC
PJ7A-5B(AIDC LED)
PJ7A-6B(GND)
PJ7A-7B(AIDC OUT)
4002C21TAA