T-30
C004C Ventilation Fan Motor’s
failure to turn
• The Lock signal remains HIGH for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has started turning.
• The Lock signal remains LOW for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has stopped turning.
C004E Power Supply Unit Cool-
ing Fan Motor 1’s failure
to turn
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning at high speed.
C004F Power Supply Unit Cool-
ing Fan Motor 2’s failure
to turn
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning at high speed.
C0072
Main Hopper Toner
Replenishing Motor’s fail-
ure to turn
• The Toner Bottle Home Position Sensor does not go
HIGH within 5 sec. after the motor has started turn-
ing.
• The Toner Bottle Home Position Sensor does not go
LOW within 10 sec. after the motor has started turn-
ing and the sensor has gone HIGH.
• The motor is stationary or the Toner Bottle Home
Position Sensor is HIGH 2 sec. after the motor has
stopped turning.
C0090
Developing Unit Drive
Motor’s failure to turn
• The Lock signal remains HIGH for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has started turning.
• The Lock signal remains LOW for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has stopped turning.
C0210
Image Transfer/Paper
Separator Corona
charge leak detected
The Charge Leak Detection signal (SCD) remains ON
for a continuous period of 0.3 sec. after the Image
Transfer/Paper Separator Corona output has been
turned ON.
C0400
Exposure Lamp’s failure
to turn ON
• During a light intensity adjustment sequence, the
CCD read data does not exceed the specified level
when the peak of the intensity of light is detected
within 1 min. after the Exposure Lamp has turned
ON.
• Under normal conditions, the CCD read data does
not exceed the specified level 450 ms after the
Exposure Lamp has turned ON.
C0420
Exposure Lamp turning
ON at abnormal timing
During a light intensity adjustment sequence, the
adjusted value for the intensity of light remains at the
lower limit and the CCD output level is at the saturation
level even after the lapse of 2 sec. after the Exposure
Lamp has turned ON.
Code
Description
Detection Timing
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......