T-29
4.
MALFUNCTIONS
The copier’s CPU is equipped with a self-diagnostics function that, on detecting a malfunc-
tion, gives the corresponding malfunction code on the Touch Panel.
Resetting a Malfunction
• Press the Trouble Reset Switch on the Tech. Rep. Setting Switches Board to reset fusing-
and Exposure Lamp-related malfunctions.
• For any other malfunctions, open and close the Front Door or turn OFF and ON the
Power Switch.
4-1.
Detection Timing by Malfunction Code
Code
Description
Detection Timing
C0000
Fusing Motor’s failure to
turn
• The Lock signal remains HIGH for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has started turning.
• The Lock signal remains LOW for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has stopped turning.
C0010
PC Drum Drive Motor’s
failure to turn
• The Lock signal remains HIGH for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has started turning.
• The Lock signal remains LOW for a continuous
period of 1.5 sec. or more after the lapse of 10 sec.
after the motor has stopped turning.
C0040
Suction Fan Motor’s fail-
ure to turn
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning at high speed.
C0042
Fusing Unit Cooling Fan
Motor’s failure to turn
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning at high speed.
C0044
EDH Fan Motor malfunc-
tion
See the relevant option service manual.
C0045
IR Cooling Fan Motor
malfunction
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has stopped turning.
C0046
PH Cooling Fan Motor 1
malfunction
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning.
C0047
PH Cooling Fan Motor 2
malfunction
The Lock signal remains HIGH for a continuous period
of 1.5 sec. or more after the lapse of 10 sec. after the
motor has started turning.
C0049
Paper source option Ver-
tical Transport Cooling
Fan Motor malfunction
See the relevant option service manual.
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......