T-46
(8)
C0210: Image Transfer/Paper Separator Corona charge leak detected
C0210
Relevant Electrical Parts
PC Drum Charge/Developing Bias HV
(HV1)
Master Board (PWB-A)
Step
Check
Result
Action
1
The Image Transfer/Paper Separator Coronas
Unit is installed properly.
NO
Correct installed position.
2
The Image Transfer/Paper Separator Coronas
wires are dirty or have snapped.
YES
Clean or change.
3
The malfunction code appears even with
PJ2HV1 unplugged.
YES
Change Master Board.
NO
Change the HV.
PWB-A
HV1
PJ2HV1
8
7
6
5
4
3
2
1
2
1
PJ12A-4B(SCD)
PJ12A-5B(Sep BIAS)
PJ12A-6B(Sep REM)
PJ12A-7B(Tra REM)
PJ12A-8B(Dev BIAS)
PJ12A-9B(Dev REM)
PJ12A-10B(GRID)
PJ12A-11B(C.G.REM)
DC24V
GND
PJ1HV1
4002C12TAA