D-9
2-3.
Removal of the Unit
(1)
Removal of the Multi Bypass Unit
(2)
Removal of the Suction Unit
1. Swing down the Front Door and slide out the Developer Unit.
2. Remove the Paper Dust Remover Assy.
3. Slide out the Fusing Unit.
4. Slide out the 1st and 2nd Drawers.
1. Open the Upper Right Door.
2. Remove two connectors and the cover.
3. Unplug two connectors.
4002D027AD
4. Remove two screws and the Upper Right Cover.
NOTE
When reinstalling the Upper Right Cover, Adjustment
of the Upper Right Door (Multi Bypass Unit).
☞
D-106
4002D028AB
5. Unplug two connectors from lower end of the Suc-
tion Unit.
4002D029AA
6. Swing the Transport Section Release Lever back to
its original position.
7. Pressing down the Transfer/Paper Separator Coro-
nas Unit, pull out of the copier.