T-43
C004F
Step
Check
Result
Action
1
Power Supply Unit Cooling Fan Motor 2 rota-
tion: the voltage across PJ6A-11 on Power
Supply Board and GND is DC24V after the
malfunction has been reset.
NO
Change Master Board.
2
Power Supply Unit Cooling Fan Motor 2 rota-
tion: the voltage across PJ6A-13 on Power
Supply Board and GND is DC5V after the mal-
function has been reset.
YES
Check motor for installa-
tion.
Change motor.
NO
Change Master Board.