T-66
(20) C0F32: ATDC Sensor malfunction
C0F33: Abnormally low T/C as detected by ATDC Sensor
C0F32, C0F33
Relevant Electrical Parts
ATDC Sensor (UN2)
Master Board (PWB-A)
Step
Check
Result
Action
1
PJ7A on Master Board, CN10, and PJ7 on the
sensor are properly connected.
NO
Plug them in securely.
2
ATDC Sensor operation: the voltage across
PJ7A-10B on Master Board and GND changes
in the range between DC0.5V and DC4.5V dur-
ing a copy cycle.
YES
Change Master Board.
NO
Change sensor.
1
1
24
24
17
17
16
16
15
15
CN10
18
18
PJ7
1
2
3
4
PWB-A
UN2
ATDC
PJ7A-8B(CONTROL)
PJ7A-9B(DC24V)
PJ7A-10B(OUT)
PJ7A-11B(GND)
4002C22TAA