T-71
5.
IMAGE FAILURE
5-1.
Image Failure Troubleshooting
• In this chapter, troubleshooting is divided into “initial checks” and “troubleshooting proce-
dures classified by image failures.”
• If any image failure has occurred, first make the initial checks, then proceed to the corre-
sponding image failure troubleshooting procedure.
5-2.
Initial Checks
• Determine if the failure is attributable to a basic cause or causes.
• Determine if the failure is attributable to an input system (IR) or output system (engine)
fault.
Section
Step
Check
Result
Action
Installation
site
1
See “PRECAUTIONS FOR
INSTALLATION” in GENERAL.
NO
Change the installation site.
Paper
2
Recommended paper is used.
NO
Instruct user.
3
Paper is damp.
YES
Change paper.
Instruct user in paper storage.
Original
4
Original not flat
YES
Correct.
5
Faint original
YES
Instruct user.
6
Highly transparent original
(OHP transparencies, etc.)
YES
Instruct user.
7
Dirty or scratched Original
Glass
YES
Clean or change.
PM parts
8
PM parts relating to image for-
mation have reached the end
of cleaning/replacement
cycles.
YES
Clean or change.
(See Maintenance Schedule.)
Check
Result
Cause
Copy made at a reduced
ratio.
Input
system
Output
system
1177T03YA
1177T04YA
1177T05YA
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......