D-63
(9)
Cleaning of the Lower Fusing Roller Thermistor
(10) Removal of the Upper Fusing Roller Thermostat
(11) Cleaning of the Upper Fusing Roller Thermostat
5. Remove the rubber stopper, and slide out the shaft.
6. Remove the Lower Fusing Roller Thermistor.
4002D185AB
1. Remove the Lower Fusing Roller Thermistor Assy.
2. Using a soft cloth dampened with oil, wipe the
Lower Fusing Roller Thermistor clean of dirt.
4002D186AA
1. Remove the Harness Guide.
2. Remove two screws and the Upper Fusing Roller
Thermostat Assy.
3. Remove two screws and the Upper Fusing Roller
Thermostat.
4002D187AA
1. Remove the Upper Fusing Roller Thermostat Assy.
2. Using a soft cloth dampened with silicone oil, wipe
the Upper Fusing Roller Thermostat clean of dirt.
4002D188AA