D-35
(8)
Removal of the EDH Glass
(9)
Removal of the Scanner Drive Cable
1. Remove the Original Glass and EDH Glass.
2. Remove the Left Cover, Right Cover, Rear Upper Cover and Control Panel.
3. Remove the CCD Unit Cover.
4. Remove the Scanner.
1. Remove four screws and the EDH Glass Holder.
2. Remove the EDH Glass.
4002D245AB
5. Unhook the springs of the Scanner Drive Cables
on the hook side, one each at the front and in the
rear.
6. Remove the front and rear Scanner Drive Cables.
4002D110AB
7. Remove three screws and the Scanner Motor
Mounting Bracket Assy.
4002D111AC
8. Remove one screw and then slide the front pulley
and bushing toward the rear.
4002D112AA