T-62
C0998
C099C
Step
Check
Result
Action
1
I/O check for Shifter Return Position Sensor
operation: the voltage across PJ7A-7A on Con-
trol Board and GND is DC5V (sensor
unblocked) and DC0V (sensor blocked).
YES
Change Control Board.
NO
Change sensor or Cabinet
Transport Board.
Change flat cable.
2
I/O check for Shifter Home Position Sensor
operation: the voltage across PJ7A-8A on Con-
trol Board and GND is DC5V (sensor
unblocked) and DC0V (sensor blocked).
YES
Change Control Board.
NO
Change sensor or Cabinet
Transport Board.
Change flat cable.
Step
Check
Result
Action
1
Shift Motor turns when the 3
rd
Drawer is slid in
with paper loaded on the Shift Tray (paper is
moved to the Main Tray).
NO
Correct drive coupling.
2
Shift Motor rotation: the voltage across PJ7A-
4B on Control Board and GND is DC0V (motor
deenergized) and DC24V (motor energized) in
step 1.
YES
Change motor or Cabinet
Transport Board.
Change flat cable.
NO
Change Control Board.
3
I/O check for Shift Motor Pulse Sensor opera-
tion: the voltage across PJ7A-3A on Control
Board and GND changes in the range between
DC0V and DC5V while the Shift Motor is turn-
ing.
YES
Change Control Board.
NO
Correct drive coupling.
Change sensor.
Summary of Contents for DI450
Page 13: ......
Page 14: ...DIS REASSEMBLY ADJUSTMENT ...
Page 15: ......
Page 138: ...SWITCHES ON PWBs TECH REP SETTINGS ...
Page 139: ......
Page 141: ......
Page 161: ...S 20 Punch Loop Adjust Tech Rep Mode Sensors Port Signals Finisher I O Check ...
Page 187: ......
Page 188: ...TROUBLESHOOTING 13430 ...
Page 189: ......