Image Optimization 5-87
The time begins at 0.
In live mode, the elapsed time is displayed. For example,
means the
elapsed time is 8 seconds.
If the image is frozen during timing, the timer stops working and the elapsed time will
be displayed after defreezing the image.
Set [Timer 1] or [Timer 2] to “OFF” and the timer stops running.
Micro-bubble Destruction
Function: to destroy the micro-bubbles left by the previous contrast imaging, or observe
the reinfusion effect in a continuous agent injecting process.
Entering: click [Destruct] on the soft menu to enable the micro-bubble destruction
function.
Parameters: set the parameters using the soft menu.
DestructAP: adjust the destruct acoustic power.
Destruct Time: adjust the destruct time with the adjusting range of 100-2000ms
Dual Live
In live mode or freeze mode, set the soft menu item [DualLive] to “ON” to enable the dual
live function. Both the contrast image (marked with “
”) and the tissue image (marked
with “
”) are displayed (the position can be changed). Use the left/right keys of soft menu
controls <4> to switch between the menus of tissue image and contrast image so that you
can adjust the corresponding parameter.
Tip:
In dual live mode, the screen displays the contrast image and tissue image
In freeze mode, only one cine review progress bar displays as the contrast image
and tissue image are reviewed synchronously.
Image position
Use [CEUSPos: XX] to adjust the position of the contrast image.
When it is selected as “Left”, the image displays at the left side of the screen.
Max FR
Function: to define FR limitation for current status. Parameters like depth, line density
and frequency may affect the frame rate of the system. This feature will confine the
max frame rate at a certain level.
The system provides 4 levels
Image Saving
Live capture
In live mode, you can save the images of interest by clicking [Pro Capture] and [Retro
Capture] or press the user-defined save key.
Cine saving
In live mode, press the <Freeze> key on the control panel to enter cine review status.
5.14.3
Measurement, Comments and Body Marks
The system supports image measurement, comment and body mark functions. For details,
see the relevant sections.