Model: MTS200 (1U)
Doc. Ref. no. : m08/om/201
Issue no. : 03
User’s Manual
Page 48 of 195
Page 48 of 195
*
: After DISPLAY UPDATE RATE option is displayed, press OK key to change its value. After OK key is
pressed, cursor will blink which indicates now you can change the value. Its minimum value is 1 second
and maximum value is 10 seconds. Values can be changed using UP/DOWN arrow of single digit on
which cursor is blinking and use LEFT/RIGHT arrow keys to change position of blinking cursor.
8. Standard EVENT Output
MTS200 provides standard Pulse event output at every minute or every hour. The pulse output present
would of 200 ms ON time.
As shown above, “LEFT” and “RIGHT” key are used to change setting of HOUR MODE. “OK” key will
save the setting and “ESC” key will reject new setting and keep old value of this parameter in effect and
come out of configuration MENU mode to RUN mode.
9. ADDITIONAL EVENT [1 to 4]
In addition to standard event output, MTS200 also provides 4 additional event outputs. This events output
can be configured from 1 second period to 86400 seconds (1 day) period. If this events are configured
with 0 value, that particular event output will be disabled and hence no pulse output will be on that
particular event. User can also configure duty cycle (ON time) of each event output as explained in next
section 12.2.3.