Model: MTS200 (1U)
Doc. Ref. no. : m08/om/201
Issue no. : 03
User’s Manual
Page 14 of 195
Page 14 of 195
Output:
TTL into 250
Ω
Pulse Width:
200 (200 mS High & 800 mS Low signal)
Interface:
BNC Female connector(Rear Panel)
No. of Ports:
1
Alarms
Three Isolated Dry Contacts to 230 VAC / 24VDC, 10 A:
1.
GPS Lost
2.
Watchdog
3.
Power Fail
Interface:
8-Way Terminal Strip
Event/RTC ON
One Event per minute or per hour or RTC ON/OFF (Configurable)
Interface:
8-Way Terminal Strip (Rear Panel)
Event contact capacity:
350V DC, 120mA maximum
IRIGB-TTL - DC Level Shift / IEEE 1344/C37.118-2005
Format:
IRIG-B(007) [IRIGB TTL] or IEEE 1344/C37.118-2005 (field
selectable)
Output:
TTL into 50 Ω
Interface:
BNC Female connector (Rear Panel)
No. of Ports:
1
Serial
COM1
Protocol:
NMEA-0183 (RMC)
Port Settings:
9600-8-N-1
Output:
RS232/RS485
**
(Factory Configurable)
Interface:
DB9 Female Connectors (Rear Panel)
No. of Ports:
1
COM2
Protocol:
NGTS / T-Format / GPZDA / GPGGA
Port Settings:
1200/2400/4800/9600/19200-7/8-N/E/O-1/2 (Configurable)
Output:
RS232/RS485
**
(Factory Configurable)
Interface:
DB9 Female Connectors (Rear Panel)
No. of Ports:
1
** RS232 is factory set
OPTIONAL
OUTPUTS
IRIGB-TTL - DC Level Shift / IEEE 1344/C37.118-2005
Format:
IRIG-B(007) [IRIGB TTL] or IEEE 1344/C37.118-2005 (field
selectable)
Output:
TTL into 50 Ω
Interface:
BNC Female connector (Rear Panel)
No. of Ports:
1
IRIGB-Modulated / IEEE 1344/C37.118-2005
Format:
IRIG-B(127)or IEEE 1344/C37.118-2005 (field selectable)