Model: MTS200 (1U)
Doc. Ref. no. : m08/om/201
Issue no. : 03
User’s Manual
Page 150 of 195
Page 150 of 195
v) Response:
Agent returns this PDU in response to above all PDUs. It contains the requested
data items along with a result code.
vi) Trap:
This PDU is quite different from other PDUs. Agent generates it in response to
particular important events. An agent only at the request of an SNMP manager application
generates a trap PDU.
vii) Inform-Request:
This PDU introduces a new pattern of communication (Manager to
Manager communication). In manager to manager communication, one manager sends
information from a MIB view to another manager.
13.3.3 SNMP Operation:
Below are few details about SNMP package installed in
mas
TER
T-Sync
device:
SNMP Versions Supported: 1 2c 3
Net-SNMP Version:
5.7.2.1
Network transport support:
Callback Unix Alias TCP UDP IPv4Base TCPBase UDPIPv4Base
UDPBase
SNMPv3 Security Modules: usm
Agent MIB code:
masibusGPSProductInfo,
masibusGPSStatus,
masibusGPSGeneral,
masibusGPSNTP,
masibusGPSNetwork,
masibusGPSSNMP,
masibusGPSNotifications,
default_modules,
snmpv3mibs,
mibII,
ucd_snmp, agent_mibs, agentx utilities
Authentication support:
MD5, SHA1
Encryption support:
DES, AES
For this device to work as SNMP agent in network device, it is necessary that SNMP service should be
active/ON and SNMP manager1 and SNMP manager2 parameters to be actively configured in device.
SNMP service can be started through front keypad or SSH/Telnet application program or webserver.
SNMP Manger can read all variables applicable in MIB files of this device with below given single
command from linux/unix based systems or from SNMP graphical based management software such as
MIB Browser or others on windows or unix based platform.
To get/walk variables from
mas
TER
T-Sync
using SNMP MIB Browser software: