Model: MTS200 (1U)
Doc. Ref. no. : - m08/om/201
Issue no.: 03
Page 85 of 195
User’s Manual
5
IPv6 Service
0 / 1
Disable(0) or enable(1) IPv6 service in
MTS200. This change will make IPv6
service effective on both eth0 & eth1
port.
Note:
Service can be restarted only
though Option “4” in Network main
menu.
Default: 0
Below table provide each parameter description for Ethernet network Miscellaneous parameters.
Command Parameter
Applicable
Value
Description
1
Syslog1 Address
Valid IPv4/IPv6
address
Syslog server1 v4/v6 format IP
address.
Default: 0.0.0.0
2
Syslog2 Address
Valid IPv4/IPv6
address
Syslog server1 v4/v6 format IP
address.
Default: 0.0.0.0
3
Bonding Enable
0 / 1
Disable(0) or enable(1) Bonding in
MTS200. This change will make
bonding applicable and configurations
for bond0 are same as Eth0.
Note:
Configurable only for dual
Ethernet MTS200.
Default : 1
Option “5” is used to view MTS200 log messages. The device is cable to log the internal system
messages, alarms in /var/log/messages file. New log is created on Power reboot of MTS200 and old
records are deleted automatically on Power reboot. Also, MTS200 can store log messages of maximum
100Kbytes after which old logs will be deleted automatically.
If user wants the system to transmit log messages to remote syslog server on UDP layer, user need to
configure the required Syslog1 and Syslog2 server address. This will cause syslog service is restart and
thereafter, MTS200 will start transmitting all new messages in /var/log/messages and alarm to remote
syslog servers and this messages will be stored in remote PC syslog message file automatically. For
remote logging of syslog messages transmitted by MTS200, it is necessary that syslog configuration file
on Server PC should be configured for accepting syslog frames over UDP layer and syslog service
should be running on server PC.
Note:
1. If MTS200 is provided with only single Ethernet option, the other Ethernet port related
parameters/configurations will be disabled and not accessible by operator.
2. As unit is shipped with DHCP settings on eth0 and eth1 port, user need to set static IP as DHCP IP
on network may change on every Power ON/OFF of the device.
3. Eth1 port is any optional port to server different network in same industry. So, the domain of eth0 and
eth1 should be separate.
4.
Option “1” always displays live running all network settings of eth0 and eth1. However, gateway of
any one of eth0 or eth1 is only displayed due to single entry in device IP routing table.
5.
To make effect of change in any Ethernet port related parameter, user should press “y” or “Y” when
start application asks to REBOOT device. Otherwise all parameters will be restored to last saved
configuration settings.