Model: MTS200 (1U)
Doc. Ref. no. : m08/om/201
Issue no. : 03
User’s Manual
Page 34 of 195
Page 34 of 195
C-NO Configuration:
C-NC Configuration:
NO
NC
C
CN21
1
2
3
NO
NC
C
CN21
1
2
3
Table 7-2 GPS LOST Relay Configuration
7.1.3
WATCHDOG relay contacts:
CN23 3-pin jumper on main card is used to change the relay contact for Watchdog relay contacts.
Operator has to remove black jumper from its current position to required position as explained in below
images.
Refer below figure for C-NO jumper position configuration and C-NC jumper position configuration.
C-NO Configuration:
C-NC Configuration:
NO
NC
C
CN22
1
2
3
NO
NC
C
CN22
1
2
3
Table 7-3 WATCHDOG Relay Configuration
7.2 COM1 terminal RS232 / RS485 output configurations:
COM1 terminal provides serial based NMEA time frame at every second once after unit boots. COM1
terminal can configured to provide NMEA time frame on RS-232 electrical standard or RS-485 electrical
standard. A COM1 terminal is configured as RS-232 output as factory default. CN12 and CN13 jumpers
on main board of unit are used to change the configuration between RS232 to RS485 standard. Please
refer below table showing the jumpers position required for RS232 and RS485 configuration.