Model: MTS200 (1U)
Doc. Ref. no. : - m08/om/201
Issue no.: 03
Page 193 of 195
User’s Manual
2) Need to configure broadcast option in NTP client ntp settings and then restart NTP service at
client side.
3) Authentication type should be same at MTS200 and client side if ntp authentication is used
for ntp broadcast/multicast.
4) Multicast frames may be blocked by network IT routers or gateways.
17.29 Not able to create ntp autokey files in MTS200.
Below options can be possible reasons affecting the process.
1) Autokey files in MTS200 will be created only in PC scheme as MTS200 trusted Server mode
or IFF scheme.
17.30 MTS200 webserver showing old configuration data.
Below options can be possible reasons affecting the process.
1) Old cookies or cache file stored in web browser settings. Delete old history files.
2) It is recommended to use IE 9.0+ web browser.
3) To disable MTS200 IP address in Web browser settings from storing any cookies or cache
files.
17.31 IPv6 address showing “::”.
Below options can be possible reasons affecting the process.
1) IPv6 feature may be disabled.
2) IPv6 autoconf feature is disabled and not static IPv6 address is set by user.
3) Respective Ethernet port cable is not connected in network.
17.32 IPv6 address changed while MTS200 in operation.
Below options can be possible reasons affecting the process.
1) This will happen when both Ethernet ports are configured in Bonding mode. This can occur only
when current active Ethernet port cable is disconnected from LAN and MTS200 internally
switches to other Ethernet port connected in LAN. This will result in update in IPV6 global
address according to current active Ethernet port.
17.33 IPv6 Link-Local address acquired but IPv6 Global address not acquired
Below options can be possible reasons affecting the process.
1) Autoconf feature is disabled.
2) IPv6 enabled router is not available in network.
17.34 Both Ethernet port showing same IPv6 Link-local and global address
Below options can be possible reasons affecting the process.
1) Bonding feature is enabled if both Ethernet port are connected in same network.