![Manta MTS-1700 SERIES Operation And Reference Manual Download Page 322](http://html1.mh-extra.com/html/manta/mts-1700-series/mts-1700-series_operation-and-reference-manual_1723616322.webp)
MTS-1730 INPUT/OUTPUT SIGNAL CONDITIONER
B-2 MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
B.3 ORDERING INFORMATION
MTS-1730
Basic unit, including case, carry handle (two input modules and two output
modules, included as standard).
Can accommodate up to four input modules and four output modules in total.
•
Option -02
240VAC, 50/60 Hz line input
•
Option -03C1-5
Input module, containing four isolated 3-terminal channels, LED indicators,
and test pushbutton. (5V logic voltage sensing)
•
Option -03C1-12
Input module, containing four isolated 3-terminal channels, LED indicators and
test pushbutton. (12V or greater logic voltage sensing)
•
Option -03C2-5
16 channel input module, 3-terminal channels, LED indicators.
(5V logic voltage sensing)
•
Option -03C2-12
16 channel input module, 3-terminal channels, LED indicators. (12V or greater
logic voltage sensing)
•
Option -03D
Output module, four isolated channels with five-way binding posts, LED
indicators, and test pushbuttons. Variations available listed below.
•
Option -05
1 Year extended warranty
Additional year for a total of two years.
•
Option -11
Hardshell shipping case
•
Option -14
Cordura carry case
•
Option -14
19” Rackmount enclosure
Order code
Type
Voltage rating
Current rating
Output type
Switching
speed
Application
Option -03D1
Standard
300V DC/AC
300mA
DC/AC
Reed relay
0.25ms
typ., 0.5ms
max.
General
purpose
Option -03D2
High speed
300V DC/AC
150mA DC,
250mA AC
MOSFET
50us typ.,
100 us max.
High speed
signals
(e.g. phase
comparison)
Option -03D4
High current
75V DC or
60V AC
50A DC/AC
Form A
contact
relay
8 ms max
operate,
3 ms max.
release
Current routing