MTS-1750 HIGH CURRENT SOURCE - Section 10
10-12 MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
•
Connect the outputs of the MTS-1750 to the device under test.
•
Connect the AC input power to the MTS-1750, and turn it on. WARNING – OUTPUTS MAY BE
LIVE WHEN MTS-1750 MAIN POWER SWITCH IS ON. TURN OFF MAIN POWER
SWITCH BEFORE MAKING WIRING CHANGES.
FIGURE 10.9 MTS-1750 CONTROL CONNECTOR CONNECTIONS
FOR STAND ALONE OPERATION
Operation
The function generator controls the MTS-1750 output current. This configuration has a gain of 20 (e.g. if
the amplitude of the function generator is 0.5 V, the MTS-1750 will output a current of 10.00 A). The
acceptable range of control voltage is 100mV to 5.0V (control voltage can go as low as 0; however, the
signal may be distorted slightly). All adjustments, including amplitude, frequency and general signal
shape, are controlled by the function generator.
CONTROL
+ Terminal of
Function Generator
- Terminal of
Function Generator
Short Amplifier
Enable
to Ground
1
2
3
4
9
13
11 12
10
14
7
15
8
6
5
- Terminal of
Voltage Meter
+ Terminal of
Voltage Meter