![Manta MTS-1700 SERIES Operation And Reference Manual Download Page 22](http://html1.mh-extra.com/html/manta/mts-1700-series/mts-1700-series_operation-and-reference-manual_1723616022.webp)
TABLE OF CONTENTS
xxii MTS-1700 SERIES OPERATION AND REFERENCE MANUAL
MANTA TEST SYSTEMS
CU A002 15A
AN26 - APPLICATION NOTE
RETRIEVING AND PLAYBACK OF OSCILLOGRAPHY
WAVEFORMS
1.0
INTRODUCTION ...................................................................................... GG-1
2.0
PROCEDURE............................................................................................. GG-1
2.0.1
Retrieving and Converting SEL321 Oscillography files to COMTRADE
format.................................................................................................... GG-1
2.0.2
Retrieving and converting DLP Oscillography files to COMTRADE
format.................................................................................................... GG-2
2.0.3
Retrieving and converting ABB REL512 Oscillography files to
COMTRADE format ............................................................................ GG-2
2.0.4
Downloading COMTRADE files to the MTS-1700 System ............... GG-3
AN27 - APPLICATION NOTE
TESTING THE HIGH IMPEDANCE DETECTION OF THE GE DFP200
1.0
INTRODUCTION ...................................................................................... HH-1
2.0
MANUAL TESTING PROCEDURES OF THE GE DFP200
HIGH IMPEDANCE DETECTION ALGORITHM.................................. HH-1
2.1
ARCING TEST PROCEDURE.................................................................. HH-3
3.0
PROCEDURES OF USING THE PROGRAMMABLE FAULT
SPREADSHEET......................................................................................... HH-3
3.1
FEATURES AND DESCRIPTION............................................................ HH-3
3.2
PROCEDURES .......................................................................................... HH-4
3.3 PLAYING THE PROGRAMMABLE FAULT ......................................... HH-5
3.4
SUMMARY OF USEFUL COMMANDS ................................................. HH-5
4.0
TESTING PROCEDURES OF THE GE DFP200 HIGH IMPEDANCE
DETECTION ALGORITHM USING FAULT PLAYBACK ................... HH-5
4.1 DOWN CONDUCTOR TEST.................................................................... HH-5
4.2 ARCING TEST........................................................................................... HH-7
5.0 OTHER USES FOR FAULT PLAYBACK SPREADSHEET .................. HH-7
6.0 REFERENCES ........................................................................................... HH-7
AN28 - APPLICATION NOTE
KD-4 RELAY TEST PROCEDURE USING THE MTS-1710 TEST EQUIPMENT
1.0
INTRODUCTION ...................................................................................... II-1
2.0
DESCRIPTION OF RELAY ...................................................................... II-1
3.0
EQUIPMENT REQUIRED AND CONNECTIONS ................................. II-1
4.0
SAFETY WARNINGS AND PRECAUTIONS......................................... II-1
5.0
MHO CIRCLES AND MTA ...................................................................... II-2
5.1
SETTINGS, CALCULATION OF RELAY REACH AND MTA............. II-2
5.1.1
Phase-Phase element MHO circle, A-B Faults ..................................... II-3
5.1.2
Phase-Phase element MHO circle, B-C Faults ..................................... II-5
5.1.3
Phase-Phase element MHO circle, C-A Faults ..................................... II-5
5.2
PHASE-PHASE ELEMENT MTA ............................................................ II-5
5.3
THREE-PHASE ELEMENT MHO CIRCLE ............................................ II-6
5.4
TESTING THE THREE-PHASE ELEMENT MTA.................................. II-6
5.5
TARGET (CURRENT OPERATED) ........................................................ II-6
6.0
OPERATING SPEED................................................................................. II-7