Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0244
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
•
806f0a13-0302ffff : A Fatal Bus Error has occurred on system [ComputerSystemElementName].
(CPU 2 PECI)
This message is for the use case when an implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130302ffff or 0x806f0a130302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0244
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
•
81010002-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower non-critical)
has deasserted. (CMOS Battery)
This message is for the use case when an implementation has detected a Lower Non-critical sensor
going low has deasserted.
732
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......