816f0a13-0301ffff : System [ComputerSystemElementName] has recovered from a Fatal Bus
Error. (CPU 1 PECI)
This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130301ffff or 0x816f0a130301ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0245
User Response
1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat
sink and Replacing a microprocessor and heat sink).
2. If the problem persists and there is no other CPU with the same error indication, replace the
system board.
3. (Trained technician only) Replace the system board (see Removing the system board and
Replacing the system board). (n = microprocessor number)
•
816f0a13-0302ffff : System [ComputerSystemElementName] has recovered from a Fatal Bus
Error. (CPU 2 PECI)
This message is for the use case when an implementation has detected that a system has recovered
from a Bus Fatal Error.
May also be shown as 816f0a130302ffff or 0x816f0a130302ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
Critical - Other
Appendix A. Integrated management module II (IMM2) error messages
1025
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......