1. Power supplies and redundant power supplies in the server must be with the same power rating,
wattage or level.
2. You may use the Power Configurator utility to determine current system power consumption. For
more information and to download the utility, go to http://www.ibm.com/ systems/bladecenter/
resources/ powerconfig.html.
Acoustical noise emissions:
• Sound power, idling: 6.4 bels maximum
• Sound power, operating: 6.6 bels maximum
Notes:
1. The noise emission level stated is the declared (upper limit) sound power level, in bels, for a random
sample of machines. All measurements are made in accordance with ISO 7779 and reported in
conformance with ISO 9296.
2. The PCIe options supported in this system vary greatly in function, power draw, and required
cooling. Any increase in cooling required by these options will result in increased fan speed and
produced sound power level. The actual sound pressure levels measured in your installation
depend upon a variety of factors, including the number of racks in the installation; the size,
materials, and configuration of the room; the noise levels from other equipment; the room ambient
temperature and pressure, and employees' location in relation to the equipment.
Heat output:
Approximate heat output:
• Minimum configuration: 525.45 Btu per hour (AC 154 watts)
• Maximum configuration: 6667 Btu per hour (AC 1954 watts)
Environment:
The Lenovo Converged HX Series appliance complies with ASHRAE class A3 specifications.
Power on:
• Temperature: 5°C–40°C (41°F–104°F) up to 950 m (3117 ft). Above 950 m (3117 ft), de-rated
maximum air temperature is 1°C (33.8°F) per 175 m (574 ft).
• Humidity, non-condensing: -12°C dew point (10.4°F) and 8%–85% relative humidity.
• Maximum dew point: 24°C (75°F)
• Maximum altitude: 3050 m (10000 ft) and 5°C–28°C (41°F–82°F)
• Maximum rate of temperature change: 20°C/hr (68°F/hr) for HDDs
Power off:
• Temperature: 5°C–45°C (41°F–113°F)
• Relative humidity: 8%–85%
• Maximum dew point: 27°C (80.6°F)
Storage (non-operating):
• Temperature: 1°C–60°C (33.8°F–140°F)
• Altitude: 3050 m (10000 ft)
• Relative humidity: 5%–80%
• Maximum dew point: 29°C (84.2°F)
Shipment (non-operating):
8
HX3510-G, HX5510, HX5510-C, HX7510 Installation and Service Guide
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......