Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix:
PLAT
ID:
0186
User Response
1. Make sure the server meets the minimum configuration to start (see Power-supply LEDs).
2. Update the server firmware on the primary page. Important: Some cluster solutions require
specific code levels or coordinated code updates. If the device is part of a cluster solution, verify
that the latest level of code is supported for the cluster solution before you update the code.
3. (Trained technician only) Replace the system board.
•
806f0113-0301ffff : A bus timeout has occurred on system [ComputerSystemElementName].
(CPU 1 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130301ffff or 0x806f01130301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0224
User Response
1. Reseat the microprocessor, and then restart the server.
2. Replace microprocessor n. (n = microprocessor number)
•
806f0113-0302ffff : A bus timeout has occurred on system [ComputerSystemElementName].
(CPU 2 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
Appendix A. Integrated management module II (IMM2) error messages
503
Summary of Contents for HX3510-G
Page 1: ...HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide Machine Type 8695 ...
Page 6: ...iv HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 62: ...50 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 102: ...90 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 112: ...100 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1222: ...1210 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1238: ...1226 HX3510 G HX5510 HX5510 C HX7510 Installation and Service Guide ...
Page 1239: ......
Page 1240: ......