![background image](http://html1.mh-extra.com/html/lacie/131018-storview-snapshot-mac/131018-storview-snapshot-mac_user-manual_3250746069.webp)
Configuring a Storage Solution
61
6.4.4 Auto Spare
The Auto Spare option, when enabled, will automatically cause a replacement disk drive when inserted
to be used as a dedicated hot spare for the failed drive and its array. When a new drive is inserted in
place of the failed drive, a rebuild operation will begin automatically using the new drive. This option is
useful when a global or dedicated hot spare drive is not assigned and you have a fault tolerant array that
experiences a drive failure. This option allows the user to just insert a replacement drive and the rebuild
will begin, instead of opening the Drive Information window for the replacement disk drive and assigning
it as a hot spare. Refer to the Spare Drive Rules
on page 57
.
1
To enable this feature, click the
Advanced Settings
icon on the Main screen Tool Bar. The Advanced
Settings window will open.
2
Place the mouse pointer on the check box next to the
Auto Spare
parameter and click to place a check
mark enabling the feature.
3
Click the
APPLY
button and click the
CLOSE
button on the confirmation window when it appears.
4
Then click the
CLOSE
button on the Advanced Settings window.
Figure 6–16
Advanced Settings Window
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...