StorView RAID Module
94
9.2.2 Fault Tolerance
In the Fault Tolerance section, you can enable or disable controller features that improve the controllers
abilities to maintain a level of fault tolerance.
• Auto Spare - This option when selected allows the data to be rebuilt on the drive that is inserted into
the slot from which the failed drive was removed. This is beneficial when a hot spare or global spare
is not designated for a fault tolerant array and a drive fails in that array.
• Auto Rebuild - Selecting this option will automatically start a rebuild operation when a fault-tolerant
array loses a drive member and a replacement or hot spare drive is available and online. When you
assign a hot spare (dedicated or global) this option is automatically enabled. After creation of the
hot spare, the option can be disabled if desired.
• Single Controller Mode - When operating in the StandAlone mode (single controller configurations)
selecting this option stops the controller from constantly checking for a partner controller. When
operating a duplex Active-Active configuration, deselect this option.
• Background Drive Verification - This option when selected is used to automatically verify the media
of all drives in the background. If a media error is detected, the controller can automatically re-write
the data, providing that the array is in a fault tolerant mode. As stated this process occurs in the
background when microprocessor time is available and is suspended when processor time is not
available.
• Auto Update Drive Firmware - Selecting this option allows the disk drive firmware to be automatically
updated when a drive has been updated using the VT-100 menu based system. Any time a
matching drive identical to the drive you updated in the system is discovered, it will automatically
update those drives firmware. StorView will display an icon that the firmware is being updated in the
enclosure front view graphical display on the Main screen.
Figure 9–4
Advanced Settings Window
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...