Event Logs
159
14.6.4 Drive and Array Events
These events are related to the drives, loops (where applicable) and disk arrays. The ID is given in the
format of its hexadecimal value which is seen in Unix operating systems and its equivalent decimal value
in parenthesis which is seen in the Microsoft Windows operating system.
Drive & Array Event
Messages
Type [ID]
Cause
Action
The drive w/SN <
xxxxxxx
>
(Slot <
nn
>, Enclosure <
nn>
)
(<
Array Name
> Drive
<
member index
>) has failed
due to an unrecoverable error.
Sense Data: <
xx
>/<
xx
>/<
xx
>.
Error
[0xB0A (2826)]
Typically due to a non-
recoverable media error
or hardware error.
Replace the disk drive.
The drive w/SN <
xxxxxxx
>
(Slot <
number
>) (Drive
<
number
>) has been marked
as failed because it was
removed.
Error
[0xB0B (2827)]
Drive has been removed
or bypassed by the user,
or has a serious
hardware error.
Removal of cables
connecting the
enclosures.
Replace the disk drive.
Replace the cables.
Rebuilding has failed due to an
unrecoverable error on the
new drive w/SN <
xxxxxxx
>
(Slot <
nn
> (Drive <
number
>) in
the array.
Error
[0xB0C (2828)]
Typically due to a non-
recoverable media error,
or hardware error.
Replace with a new drive
and initiate a rebuild.
Rebuilding has failed due to an
unrecoverable error on the
new drive w/SN <
xxxxxxx
>
(Slot <
nn
>, Enclosure <
nn
>)
(<
Array Name
> Drive <
num
>).
Error
[0xB0D (2829)]
Typically due to a non-
recoverable media error
or hardware error.
Backup all data and
restore to a new array.
The drive w/SN <
xxxxxxx
>
(Slot <
nn
>, Enclosure <
nn
>)
(Slot <
number
>) (Drive
<
number
>) has failed due to a
time-out.
Error
[0xB0E (2830)]
Drive error.
Replace the disk drive.
Disabled Enclosure <
name
>
Slot <
nn
> due to excessive
errors.
Error
[0xB13 (2835)]
This indicates that the
controller has shutdown
the slot due to multiple
errors from the drive.
This may be due to a bad
drive or MUX Transition
card.
Remove the drive in the
identified slot will re-
enable the PHY.
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...