StorView RAID Module
160
SATA Multiplexer switching
failure on Enclosure <
name
>
Slot <
nn
>.
Error
[0xB13 (2835)]
This indicates that the
controller has tried
multiple times to switch
the Multiplexer (MUX) on
a SATA drive and it has
not been successful.
This may be due to a bad
drive or MUX Transition
card (dongle).
Replace the disk drive
or MUX Transition Board
(dongle).
Array <
name
> is in a critical
state.
Error
[0xB1B (2843)]
Drive removal or failure.
Replace the disk drive
and rebuild the array.
The drive w/SN <
xxxxxxx
>
(Slot <
number
>) returned a
bad status while completing a
command. SCSI Info:
Operation <
type
>, Status
<
type
>.
Warning
[0xB27 (2855)]
Unknown status returned
by the disk drive.
Contact technical support
and provide them with a
copy of the event log.
The drive w/SN <
xxxxxxx
>
(Slot <
nn
>, Enclosure <
nn
>)
timed out for the SCSI
Operation <
type
>.
Warning
[0xB28 (2856)]
Drive hardware error or
bus error.
Check cabling and
ensure the disk drives are
properly seated.
A rebuild has started on the
drive w/SN <
xxxxxxx
> (Slot
<
nn
> (Drive <
number
>).
Information
[0xB30 (2864)]
A rebuild has started.
No action necessary.
A rebuild has completed on
(Array <
Name
> Drive
<
number
>).
Information
[0xB31 (2865)]
A rebuild has completed. No action necessary.
A rebuild has re-started on the
drive w/SN <
xxxxxxx
> (Slot
<
nn
> (Drive <
number
>).
Information
[0xB32 (2866)]
A rebuild has started.
No action necessary.
Array <
name>
has started
initializing.
Information
[0xB33 (2867)]
Initialization has started.
No action necessary.
Array <
name>
has completed
initializing.
Information
[0xB34 (2868)]
Initialization has
completed.
No action necessary.
A SAS command was aborted
on the drive w/WWN
<xxxxxxxxxxxxxxxx> (Slot
<
num
>, Enclosure <
num
>) for
the SCSI Op Code (
hex string
).
Warning
[0xB39 (2873)]
Aborted command.
Possible reasons are:
faulty disk drive, faulty
drive slot, fault enclosure,
cable issue, faulty drive
firmware, fault in SAS
expander, excessive
noise, or possible drive
interference.
Drive & Array Event
Messages
Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...