StorView RAID Module
84
If you want to downgrade the firmware version you must shut down one controller and flash the operating
controller. Then shut down the controller which was downgraded, bring the second controller up and flash
its firmware to the lower version. Then start both controllers and resume operations.
1
Click the
Controller
icon located just above the Tool Bar.
The Controller Information window will open.
2
Click the “UPDATE CONTROLLER FW” button.
Figure 8–4
Main Screen (RS-1220-F4-5412E Shown)
Figure 8–5
Controller Information Window (RS-1220-F4-5412E Shown)