Event Logs
163
A rebuild was aborted on
(Array <
yy
> Drive <
ww
>).
Information
[0xB73 (2931)]
A rebuild was canceled
by the user.
No action necessary.
SATA Drive Error: (Slot
<
number
>) Information
<description>.
Error
[0xB75 (2933)]
Drive or SATA link error.
No action necessary.
A drive w/ SN <xxxxxxx> (Slot
<
nn
>) has been removed.
Error
[0xB76 (2934)]
A drive w/ WWN
<
xxxxxxxxxxxxxxxx
> (Slot
<
nn
>, Enclosure <
nn
>)
has been removed.
No action necessary.
There was a bad block during a
rebuild on Array <
nn
>, Drive
<
mm
>, LBA <
xx xx xx xx xx
xx
>, Block Count <xx>.
Warning
[0xB78 (2936)]
A bad block was detected
during the rebuild
operation. Data loss will
occur with that data
stripe.
Replace drive after
rebuild. Restore lost data
from a know good
backup.
An unsupported drive w/
(WWN <
xxxxxxxxxxxxxxxx
> or
SN) <xxxxxxx> (Target ID
<
num
>) has been inserted.
Error
[0xB7B (2939)]
A SATA drive with an A/A
MUX Transition card was
installed in a system with
an older model controller
(RS-1220-F4-5402E).
Replace the SATA drive
with one that has a A/P
MUX Transition card
installed.
<
Array Name
> is in an
unsupported configuration with
a mixture of A/P and A/A SATA
drives.
Error
[0xB8C (2956)]
The array is marked
invalid because it
contains SATA drives
with a mix of Active-
Active and Active-
Passive MUX Transition
cards.
A SATA drive with an
Active-Active MUX
Transition card is used in
a RS-1220-F4-5402E
enclosure.
Replace the offending
drive with one that
contains a matching MUX
Transition card as the
remaining drive
members.
Replace the SATA drive
with the Active-Active
MUX Transition card to
one with an Active-
Passive MUX Transition
card.
Drive & Array Event
Messages
Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...