StorView RAID Module
166
14.6.6 Enclosure Events
These events are related to the enclosure components reported by the SES processor. The ID is given
in the format of its hexadecimal value which is seen in Unix operating systems and its equivalent decimal
value in parenthesis which is seen in the Microsoft Windows operating system.
Enclosure Event Messages
Type [ID]
Cause
Action
Enclosure<
xx
> (w/
WWN:<
xxxxxxxxxxxxxxxx
>)
timed out on SCSI
command 0x02X.
Warning
[0xB79 (2937)]
This error is generated
when a command to the
Enclosure processor
time-outs.
Verify if the system has
gone to SES_LEVEL_1.
If it has, verify the
configuration.
Faulty cables, drives or
EBOD I/O or Disk I/O
module malfunction
could be the root cause
of this error.
You may occasionally
see this error during drive
insertion, failover/
failback or drive removal.
As long as the system
remains at
SES_LEVEL_3 the user
does not intervene. If this
event is periodically
posted in the event log
the user may have a hard
drive or EBOD I/O or Disk
I/O module problem. The
system should be
inspected to isolate the
problem to either drives
or EBOD I/O or Disk I/O
module.
NOTE: This event is only
valid for daisy chained
systems.
Power supply <
zz>
is OK.
Information
[0xC6B (3179)]
Normal condition
reported.
No action necessary.
Power supply <
zz>
is
operating outside of its
specification.
Warning
[0xC6B (3179)]
The specific power
supply has failed.
The specific power
supply is powered off or
mains power removed.
Replace the power
supply module module.
Ensure that the specific
power supply On/Off
switch is in the On
position (l) or mains
power is applied.
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...