15.5 Command Cluster Statistics
To increase performance, the controller can cluster sequential write commands together to create a
larger write command. This results in less commands being sent to the disk drives. Additionally, if
sufficient data is clustered by the controller, then it can perform a a full stripe write for RAID5/50/6 arrays.
This significantly improves performance. In cases where the host does not send a sufficient number of
outstanding writes, writeback cache can be used to delay the write to disk, increasing the likelihood of
clustering more data.
Figure 15–4
Statistics Screen - Command Cluster Tab
Statistic
Description
Write Cluster Rate
This is the percentage of the number of write commands that
are part of a cluster versus the total number of write
commands that have been issued. This gives an indication of
the sequential nature of the data access pattern from the host,
and of the performance of the writeback cache.
RAID 5/50/6 Full Stripe Write Rate
This is the percentage of the amount of data that is written as
a full stripe write versus the total amount of data written. This
gives an indication of the sequential nature of the data access
pattern from the host, and of the performance of the writeback
cache, for RAID 5/50/6 arrays.
Command Cluster Count
When the controller clusters a write command, it may cluster
a large number of them together. These statistics record the
average and maximum number of commands the controller
clusters, and also the percentage for each one of these
values.
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...