Event Logs
157
14.6.2 Expansion Module Events
These events are related to the expansion modules (Disk I/O or EBOD I/O module) reported by the SES
processor during updates. The ID is given in the format of its hexadecimal value which is seen in Unix
operating systems and its equivalent decimal value in parenthesis which is seen in the Microsoft
Windows operating system.
Expansion Module Event
Messages
Type [ID]
Cause
Action
Disk I/O FW upgrade started
<
Enclosure <num>
> <
Total
Enclosure <num>
> from
<
current firmware version
> to
<
new firmware version
>.
Information
[0xB7E (2942)]
The firmware upgrade of the
Disk I/O or EBOD I/O module
firmware has started. The
process uploads the firmware
to the buffer on the controller
and starts the update on the
module. The update will
occur on all the Disk I/O or
EBOD I/O modules
connected to the controller.
At the end of the update
process, if the update
process is successful, the
RAID Controller and Disk I/O
or EBOD I/O module will be
reset.
No action necessary.
Disk I/O FW upgrade finished
<
Enclosure <num>
> <
Total
Enclosure <num>
> from <
old
firmware version
> to <
new
firmware version
>.
Information
[0xB7F (2943)]
The firmware upgrade of the
Disk I/O - EBOD I/O module
firmware has completed
successfully. The RAID
Controller and Disk I/O or
EBOD I/O module will be
reset.
No action necessary.
Disk I/O FW upgrade stopped
due to error.
Error
[0xB80 (2944)]
The firmware upgrade of the
Disk I/O EBOD I/O module
firmware has stopped
because the update process
has encountered an error.
However, the update process
will resend the firmware and
continue with the process
update. At the end of the
update process, if the update
process is successful, the
RAID Controller and Disk I/O
EBOD I/O module will be
reset.
No action necessary.
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...