![LaCie 131018 - StorView Snapshot - Mac User Manual Download Page 160](http://html1.mh-extra.com/html/lacie/131018-storview-snapshot-mac/131018-storview-snapshot-mac_user-manual_3250746160.webp)
StorView RAID Module
152
The onboard cache protection
battery backup unit has failed
or has been disconnected.
Error
[0xB07 (2823)]
Battery failure.
Replace battery in the
controller.
The partner controller has
failed or has been removed.
Error
[0xB08 (2824)]
Failure or removal of one
controller (partner) in an
Active-Active
configuration.
Re-install the controller.
or
Replace the controller.
This controller has not
received a response from the
other (partner) controller in the
allotted time, and therefore it
has been disabled.
Error
[0xB09 (2825)]
Failure or removal of one
controller (partner) in an
Active-Active
configuration.
Replace the controller.
An error has been detected on
the SAS domain or with a SAS
device during the discovery
process.
Error
[0xB0F (2831)]
Possible drive or internal
bus error.
Replace drive.
The controller’s <
x
> voltage
reading measures <
aa
>V
which exceeds the limit.
Error
[0xB19 (2841)]
Voltage regulator
hardware failure.
Enclosure 5V or 12V
problem in the power
supply.
Replace the controller.
Replace the defective
Power Supply or Power
Supply/Cooling module.
Internal transfer error.
Error
[0xB1A (2842)]
Hardware problem.
Replace the controller.
Controller mismatch detected.
“This” or “The other” controller
was shut down.
Error
[0xB1C (2844)]
RAID Controllers with
different SAS controller
chips have been
installed. This is not a
supported configuration.
Replace one of the
controllers so that both
controllers are of the
same type. For example
all F5402E RAID
Controllers or all F5412E
RAID Controllers.
The other (partner) controller
has been inserted.
Information
[0xB29 (2857)]
Partner controller has
been inserted.
No action necessary.
The other (partner) controller
has passed its self-test and is
now ready (failback).
Information
[0xB2A (2858)]
Partner controller is ready
to fail back.
No action necessary.
A stripe synchronization of a
RAID set has started. This
occurs when a controller fails,
or after a controller is powered
off with write commands in
progress.
Information
[0xB2C (2860)]
A controller fails or is
powered off during a write
operation.
No action necessary.
Controller Events Messages Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...