Event Logs
153
A stripe synchronization of a
RAID set has completed.
Information
[0xB2D (2861)]
A controller fails or is
powered off during a
RAID write operation.
No action necessary.
The configuration has
changed.
Information
[0xB2F (2863)]
A change in the
configuration has
occurred.
If you are using the Save
Configuration feature, re-
save your configuration
information - it no longer
matches, otherwise no
action is necessary.
The controller is flushing the
partner’s mirrored cache to the
drives. There are <
xx
> cache
entries totalling <
yy
> 512-byte
blocks.
Information
[0xB35 (2869)]
Failure or removal of the
partner controller.
No action necessary.
The controller has completed
flushing the partner’s mirrored
cache to the drives.
Information
[0xB36 (2870)]
Completion of mirrored
cache flushing.
No action necessary.
The battery backup unit
attached to the controller is
now functioning correctly.
Line Power Mode
Information
[0xB42 (2882)]
Battery charging
complete.
Special feature mode.
Controller can be
operated with battery
removed and no LED
indication occurs.
No action necessary.
The controller has been
powered off.
Information
[0xB50 (2896)]
Removal of controller or
power.
No action necessary.
The controller has been
powered on.
Information
[0xB51 (2897)]
The controller was
powered on.
No action necessary.
The controller self-test was
successfully completed.
Information
[0xB52 (2898)]
Self-test completion on
startup.
No action necessary.
The controller self-test has
failed.
Error
[0xB53 (2899)]
Self-test failure on
startup.
Replace the controller.
The controller’s NVRAM has
been reset.
Information
[0xB54 (2900)]
Occurs first time after
production.
No action necessary.
The controller has an invalid
World Wide Name.
Error
[0xB55 (2901)]
Occurs first time after
production.
Contact technical
support.
The Event Log has been
cleared.
Information
[0xB56 (2902)]
The user has cleared the
event log.
No action necessary.
The controller has been reset. Information
[0xB57 (2903)]
User initiated a controller
reset.
No action necessary.
Controller Events Messages Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...