Event Logs
155
An SDRAM ECC error - bit
<
xx
> at address
<
xx,xx,xx,xx
.
xx
> has been
detected and corrected.
Warning
[0xB72 (2930)]
SDRAM error.
If it repeats, replace the
controller.
A configuration parameter has
been changed: <
array name
>
(Array <
number
>) has been
trusted due to a cancellation of
an initialization.
Information
[0xB74 (2932)]
A user cancelled an
initialization.
No action necessary.
Hardware Error
Additional Info: (
Advanced hex
data for customer service reps
or engineer use.
).
Error
[0xB7A (2938)]
The controller will
continue to function,
however the SES
temperature sensing may
not function properly.
Replace the controller.
Running <
version_number
>
CEMI firmware version:
Release <
num
>, Build <
num
>.
Information
[0xB89 (2953)]
CEMI firmware is current. No action necessary.
“Automatic” or “Manual” CEMI
firmware upgrade from
<
original CEMI FW version
>:
Release <
num
>, Build <
num
>
to new version: Release
<
num
>, Build <
num
>
<
completed successfully>, <i
s
underway
>, or <
failed
>.
“Automatic” or “Manual”,
depending on whether the
upgrade attempt was
automatic or manual.
Error
[0xB89 (2953)]
Firmware is attempting to
upgrade.
No action necessary.
CEMI firmware upgrade from
<
original CEMI FW version
>:
Release <
num
>, Build <
num
>
to new version: Release
<
num
>, Build <
num
> failed
because there is no response
from the processor.
Error
[0xB89 (2953)]
Firmware failed to
upgrade due to non-
responding controller.
No action necessary.
Occurs when there is a remote
request to restart Embedded
module.
A remote request for a
Embedded module reset was
successful.
Information
[0xB8A (2954)]
Embedded module reset
was successful.
No action necessary.
Controller Events Messages Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...