![background image](http://html1.mh-extra.com/html/lacie/131018-storview-snapshot-mac/131018-storview-snapshot-mac_user-manual_3250746175.webp)
Event Logs
167
Power supply <
zz>
is in a
critical state.
Warning
[0xC6B (3179)]
The specific power
supply has failed.
The specific power
supply is powered off or
mains power removed.
The power supply was
removed.
Replace the power
supply.
Ensure that the specific
power supply On/Off
switch is in the On
position (l) or mains
power is applied.
Power supply <
zz>
is in an
unrecoverable state.
Error
[0xC6B (3179)]
The power supply was
removed.
Re-insert the power
supply, connect the
power cord.
Power supply <
zz>
is not
installed.
Error
[0xC6B (3179)]
The power supply was
removed.
Re-insert the power
supply, connect the
power cord and power
on, if necessary.
Fan <
zz>
is OK.
Information
[0xC6C (3180)]
Normal condition
reported.
No action necessary.
Fan <
zz>
does not support
status detection.
Information
[0xC6C (3180)]
Unknown status.
No action necessary.
Fan <
zz>
is not installed.
Information
[0xC6C (3180)]
Cooling fan module was
removed.
Re-inset the cooling fan
module, connect the
power cord and power
on, if necessary.
Fan <
zz>
is in a critical state.
Additional information may
appear:
The fan is stopped.
The fan is running at its lowest
speed.
The fan is running at its second
lowest speed.
The fan is running at its third
speed level.
The fan is running at its forth
speed level.
The fan is running at its fifth
speed level.
The fan is running at its
intermediate speed.
The fan is running at its highest
speed.
Error
[0xC6C (3180)]
A specific fan failure.
Total fan module failure.
Replace the cooling fan
module.
Temperature sensor <
zz
> is
OK.
Information
[0xC6D (3181)]
Temperature sensors are
reporting normal
temperatures in the
enclosure.
No action required.
Enclosure Event Messages
Type [ID]
Cause
Action
Summary of Contents for 131018 - StorView Snapshot - Mac
Page 28: ...StorView RAID Module 20...
Page 34: ...StorView RAID Module 26...
Page 76: ...StorView RAID Module 68...
Page 79: ...SAN LUN Mapping 71 Figure 7 2 SAN LUN Mapping Screen RS 1220 F4 5402E Shown...
Page 88: ...StorView RAID Module 80...
Page 98: ...StorView RAID Module 90...
Page 150: ...StorView RAID Module 142...
Page 184: ...StorView RAID Module 176...
Page 202: ...StorView RAID Module 194...
Page 208: ...StorView RAID Module 200...
Page 214: ...StorView RAID Module 206...