72
Keysight EXG and MXG X-Series Signal Generators User’s Guide
Optimize Performance
Using the Dual Power Meter Display
1.
Setup for Step Sweep.
“Configuring a Swept Output” on page 46
.
2.
Connecting the Channel A power sensor: Connect USB sensor to the signal generator. The
MXG/EXG should display a message across the bottom that reads similar to:
USB TMC488 device (USB POWER SENSOR,MY47400143) connected
Figure 4-4
MXG/EXG Displays Connection to U2000 USB Power Sensor
3.
Press
Aux Fctn
>
Power Meter Measurements
>
Channel A Setup
>
Connection Settings
>
Connection Type
>
USB Device (None)
>
USB POWER SENSOR (MY47400143)
4.
Press
Return
>
Zero Sensor
A diagnostic dialog box appears the
initial
time that a U2000 Series power sensor with a
different serial number is connected to the signal generator (refer to
). After the
U2000 has been recognized by the signal generator, the U2000 power sensor is saved as a
softkey in the instrument and the dialog box in
won’t be displayed (press
DONE
, if
you see this message).
Figure 4-5
Diagnostic Dialog Box for USB Sensor
A
Running Calibration(s)
bar is displayed on the signal generator. Refer to
Verify RF Output power is off before continuing.