![Keysight Technologies N5171B EXG User Manual Download Page 408](http://html1.mh-extra.com/html/keysight-technologies/n5171b-exg/n5171b-exg_user-manual_1962194408.webp)
392
Keysight EXG and MXG X-Series Signal Generators User’s Guide
Custom Digital Modulation (Option 431)
Using the Arbitrary Waveform Generator
Creating a Multicarrier Digital Modulation Setup
1.
Press
Preset
.
2.
Press
Mode
>
ARB Custom Modulation
>
Multicarrier Off On
to
On
.
3.
Press
Multicarrier Setup
>
Select Carrier and Initialize Table
>
Carrier Setup
>
EDGE
>
Done
.
Modifying Carrier Frequency Offset
1.
Highlight the
Freq Offset
value (
500.000 kHz
) for the carrier in row 2.
2.
Press
–625
>
kHz
.
Modifying Carrier Power
1.
Highlight the
Power
value (
0.00 dB
) for the carrier in row 2.
2.
Press
–10
>
dB
.
You now have a custom 2–carrier EDGE waveform with a carrier at a frequency offset of
–625 kHz and a power level of –10.00 dBm, as shown in the following figure.
Generating the Waveform
Press
Return
>
Digital Modulation Off On
.
This generates a waveform with the custom, multicarrier, EDGE state created in the previous
sections. The display changes to
Dig Mod Setup: Multicarrier (Modified)
. During
waveform generation, the
DIGMOD
and
I/Q
annunciators appear and the new custom, multicarrier,
EDGE state is stored in volatile memory. The waveform is now modulating the RF carrier.
For instructions on storing this custom, multicarrier, EDGE state to non–volatile memory, see
“Storing a Custom Multicarrier Digital Modulation State” on page 393
.
Configuring the RF Output
1.
Set the RF output frequency to 890.01 MHz.
2.
Set the output amplitude to
−
10 dBm.
3.
Press
RF On/Off
.
The custom multicarrier EDGE signal is now available at the RF OUTPUT connector.
If Digital Modulation is already on, you
must press Apply Multicarrier to apply
the changes and generate a new
custom multicarrier digital modulation
waveform based on the updated
values.
For details on each key, use key help
as described on
.