380
Keysight EXG and MXG X-Series Signal Generators User’s Guide
Custom Digital Modulation (Option 431)
Using the Arbitrary Waveform Generator
2.
Set the output amplitude to
−
5 dBm.
3.
Press
RF On/Off
.
The predefined EDGE signal is now available at the signal generator’s RF OUTPUT connector.
Creating a Custom Digital Modulation State
In this procedure, you learn how to set up a single–carrier NADC digital modulation with
customized modulation type, symbol rate, and filtering.
Figure 16-18
Setting a Digital Modulation Filter
This softkey label updates to reflect the
current modulation standard.
Mode
>
ARB Custom Modulation
>
Single Carrier Setup
This softkey
sets the filter
bandwidth
parameter,
alpha. The
default Alpha
value changes
with the
modulation
standard (see
and modulation
type selected
(see
For details on each key, use key help as described on
This softkey sets
the filter shape.
Opens a menu to select a
IS-95 filter.