SRX5800 Services Gateway Craft Interface Fan LEDs | 39
SRX5800 Services Gateway Craft Interface Online Buttons | 39
SRX5800 Services Gateway Craft Interface Alarm Relay Contacts | 42
SRX5800 Services Gateway Chassis
The services gateway chassis is a rigid sheet metal structure that houses all the other services gateway
components (see
, and
). The chassis measures
27.75 in. (70.49 cm) high, 17.37 in. (44.11 cm) wide, and 23.0 in. (58.42 cm) deep (from the front-mounting
flanges to the rear of the chassis). The chassis installs in 19-in. equipment racks or telco open-frame racks.
The chassis can be installed in standard 800-mm (or deeper) enclosed cabinets when powered by
standard-capacity power supplies, or in 1000-mm (or deeper) enclosed cabinets when powered by
high-capacity power supplies.
Up to three services gateways can be installed in one standard (48 U) rack if the rack can handle their
combined weight, which can be greater than 1,134 lb (515 kg). See
“SRX5800 Services Gateway Physical
for physical specifications for the SRX5800 Services Gateway.
Mounting hardware includes front-mounting flanges on the front of the chassis, and two center-mounting
brackets attached to the center of the chassis.
WARNING:
To meet safety and electromagnetic interference (EMI) requirements and
to ensure proper operation, you must properly ground the services gateway chassis
before connecting power. See
“Grounding the SRX5800 Services Gateway” on page 239
for instructions.
CAUTION:
Before removing or installing components of a services gateway, attach
an ESD strap to an ESD point and place the other end of the strap around your bare
wrist. Failure to use an ESD strap can result in damage to the services gateway.
29
Summary of Contents for SRX 5800
Page 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Page 23: ......
Page 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Page 111: ...LEDs 112 ...
Page 121: ...Port and Interface Numbering 122 ...
Page 127: ...Port and Interface Numbering 128 ...
Page 161: ......
Page 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Page 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Page 205: ......
Page 261: ......
Page 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Page 365: ...Figure 143 Installing an SPC 366 ...
Page 367: ...368 ...
Page 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Page 423: ......
Page 457: ......
Page 473: ...475 ...
Page 476: ...Restricted Access Area Warning 478 ...
Page 483: ...485 ...
Page 496: ...Jewelry Removal Warning 498 ...
Page 499: ...Operating Temperature Warning 501 ...
Page 509: ...DC Power Disconnection Warning 511 ...
Page 513: ...DC Power Wiring Sequence Warning 515 ...
Page 516: ...DC Power Wiring Terminations Warning 518 ...
Page 519: ...DC Power Disconnection Warning 521 ...
Page 523: ...DC Power Wiring Sequence Warning 525 ...