Table 69: Chassis Component Alarm Conditions on SRX5400, SRX5600, and SRX5800 Services
Gateways (continued)
Alarm
Severity
Remedy
Alarm Condition
Chassis
Component
Red
Open a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
Abnormal exit in the current
flow sessions of an SPU.
Service
Processing Card
(SPC)
Red
Check the status of all fan
trays.
CPU Digital Thermal Sensor
(DTS) of the SPC reaches
high or over temperature
threshold.
Red
Check the status of all fan
trays.
FPC airflow temperature
sensors in SRX5K-SPC3
reach high or over or
crosses fire temperature
threshold.
Yellow
If the alarm is present
consistently, then it
indicates a hardware issue.
Open a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
FPC airflow temperature
sensors in SRX5K-SPC3
read/access failure.
Red
Open a support case using
the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822
(toll free, US & Canada) or
1-408-745-9500 (from
outside the United States).
SRX5K-SPC3 checks for
missing devices during boot
and reports.
Red
428
Summary of Contents for SRX 5800
Page 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Page 23: ......
Page 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Page 111: ...LEDs 112 ...
Page 121: ...Port and Interface Numbering 122 ...
Page 127: ...Port and Interface Numbering 128 ...
Page 161: ......
Page 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Page 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Page 205: ......
Page 261: ......
Page 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Page 365: ...Figure 143 Installing an SPC 366 ...
Page 367: ...368 ...
Page 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Page 423: ......
Page 457: ......
Page 473: ...475 ...
Page 476: ...Restricted Access Area Warning 478 ...
Page 483: ...485 ...
Page 496: ...Jewelry Removal Warning 498 ...
Page 499: ...Operating Temperature Warning 501 ...
Page 509: ...DC Power Disconnection Warning 511 ...
Page 513: ...DC Power Wiring Sequence Warning 515 ...
Page 516: ...DC Power Wiring Terminations Warning 518 ...
Page 519: ...DC Power Disconnection Warning 521 ...
Page 523: ...DC Power Wiring Sequence Warning 525 ...