Processor subsystem, which includes a 1.2-GHz CPU, system controller, and 1 GB of SDRAM.
•
LEDs on the faceplate that indicate the SPC and SPU status.
SPC with four SPUs
Description
•
Junos OS Release 12.1X44-D10 and later
Software
release
CHASSIS CLUSTER CONTROL 0 and CHASSIS CLUSTER CONTROL 1–SFP ports for control links
in chassis cluster configurations.
Supported SFP transceivers:
1000BASE-LH (model numbers SRX-SFP-1GE-LH, SRX-SFP-1GE-LH-ET)
1000BASE-LX (model numbers SRX-SFP-1GE-LX, SRX-SFP-1GE-LX-ET)
1000BASE-SX (model numbers SRX-SFP-1GE-SX, SRX-SFP-1GE-SX-ET)
Cables and
connectors
None
Controls
•
SRX5400–Any slot, except the bottom slot 0 which is reserved for SCB/RE.
•
SRX5600–Any slot, except the bottom slots 0 or 1 which are reserved for SCB/RE.
•
SRX5800–Any slot, except the slots 0 or 1 which are reserved for SCB/RE.
Supported Slots
475 W typical, 585 W maximum
NOTE:
•
In the SRX5600 and SRX5800 Services Gateways, you must have high-capacity power supplies
(either AC or DC) and high-capacity fan trays installed in the services gateway in order to install
and use SRX5K-SPC-4-15-320 SPCs. If you do not have high-capacity power supplies and fan
trays installed, the services gateway will log an alarm condition when it recognizes the
SRX5K-SPC-4-15-320 SPCs.
•
On SRX5600 Services Gateways with AC power supplies, we recommend that you use high-line
(220v) input power to ensure the device has adequate power to support SRX5K-SPC-4-15-320
SPCs.
Power
Requirement
Approximately 18 lb (8.3 kg)
Weight
111
Summary of Contents for SRX 5800
Page 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Page 23: ......
Page 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Page 111: ...LEDs 112 ...
Page 121: ...Port and Interface Numbering 122 ...
Page 127: ...Port and Interface Numbering 128 ...
Page 161: ......
Page 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Page 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Page 205: ......
Page 261: ......
Page 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Page 365: ...Figure 143 Installing an SPC 366 ...
Page 367: ...368 ...
Page 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Page 423: ......
Page 457: ......
Page 473: ...475 ...
Page 476: ...Restricted Access Area Warning 478 ...
Page 483: ...485 ...
Page 496: ...Jewelry Removal Warning 498 ...
Page 499: ...Operating Temperature Warning 501 ...
Page 509: ...DC Power Disconnection Warning 511 ...
Page 513: ...DC Power Wiring Sequence Warning 515 ...
Page 516: ...DC Power Wiring Terminations Warning 518 ...
Page 519: ...DC Power Disconnection Warning 521 ...
Page 523: ...DC Power Wiring Sequence Warning 525 ...