background image

 
 

 

Documentation 

 

KNX OPUS 

Gateway 

 

 
 
 

 
 

 
 

 
 

Controlling and visualization of the 

OPUS MCU610 System with the EIB/KNX 

 

Order number: E001-H028001 

Summary of Contents for KNX OPUS

Page 1: ...Documentation KNX OPUS Gateway Controlling and visualization of the OPUS MCU610 System with the EIB KNX Order number E001 H028001...

Page 2: ...ts component parts 4 COPYRIGHT All title and copyrights in and to the SOFTWARE PRODUCT including but not limited to any images photographs animations video audio music text and applets incorporated in...

Page 3: ...which are options Only qualified persons are allowed to install our units Softwaredesign and Coding Michael Herbst Documentation Michael Herbst Editor Steffen Kiene b b Automations und Steuerungstech...

Page 4: ...nstruction 10 Parametrisation with the b b Terminal software 11 Automatic USB driver installation 11 Manual USB driver installation 11 Establish a connection with the KNX OPUS Gateway 15 Configure gat...

Page 5: ...S Gateway can handle up to 200 configuration channels Rail mounted device 6TE 105mm with integrated 85V 260V wide range power supply Field of application Simple integration of OPUS MCU610 controller i...

Page 6: ...or visualization of OPUS MCU610 states like e g Volume Balance in the EIB KNX system On the other hand it is possible to execute OPUS instructions from the EIB KNX bussystem with an EIB KNX switch lik...

Page 7: ...er screw terminals max 2 x 2 5mm solid wire max 2 x 1 5mm flexible wire Power consumption 30mA Temperature range 0 C 50 C in operation 0 C 70 C storage Degree of protection IP20 Interfaces 1 RS 232 co...

Page 8: ...ew Figure 2 Connection overview KNX OPUS Gateway A1 USB USB connector Mini USB Typ B A2 RS232 Serial connection RS 232 to OPUS MCU610 A3 KNX EIB KNX connector A4 L1 N Power supply 85V 260V AC L1 Phase...

Page 9: ...Button again LED Function USB LED flashing A data transmission between the PC and the KNX OPUS Gateway over the USB inter face is in progress OPUS TX LED flashing The KNX OPUS Gateway sends a telegram...

Page 10: ...with a standard bus connector Connect your OPUS MCU610 controller via the RS 232 Port 3 to the KNX OPUS Gateway Use a D Sub 9 pole serial 1 1 cable male female for this connection Connect the power s...

Page 11: ...matic USB driver installation There s a setup package available which automatically selects and installs the correct driver required by your operating system To start the setup procedure doubleclick t...

Page 12: ...second step of the Hardware Wizard select the option Install from a list or specific location Ad vanced and click again on the Next button Figure 6 Found New Hardware Wizard step 2 In the last step o...

Page 13: ...t dialog Finish the Found New Hardware Wizard by pushing the Finish button Figure 8 Found New Hardware Wizard successful After installing the driver for the USB Serial Converter the Found New Hardware...

Page 14: ...12 KNX OPUS Gateway Page 14 of 25 b b Automations und Steuerungstechnik GmbH KNX OPUS GATEWAY DOC Figure 9 Found New Hardware Wizard successful Finish the Found New Hardware Wizard by pushing the Fini...

Page 15: ...ose the window with the OK button In all versions 1 32 you need to setup the virtual COM port of your connected KNX OPUS GW manually Please proceed as follows To establish a connection with your KNX O...

Page 16: ...ric settings After you ve setup the connection close the window by clicking on the OK button To start the com munication with your KNX OPUS Gateway you have to click on the green arrow button in the t...

Page 17: ...ch the above EIB KNX group address is written cyclic can be speci fied in the field Send Interval Activating the checkbox Auto ACK activates the Auto ACK mode in the KNX OPUS Gateway In the Auto ACK m...

Page 18: ...in the fields OPUS MCU and OPUS Zone for which you want to configure your channel Next there are two sections for configuration maybe one of them is disabled depending on the OPUS instructions you ve...

Page 19: ...he OPUS in struction 11S0105 to your OPUS system If you choose the 1 Bit Binary entry in the combobox KNX Data Format you can use e g an EIB KNX switch to control the OPUS instruction Input Select If...

Page 20: ...ells the gateway that a WriteValue to the paramet rised EIB KNX group address should always send an OPUS instruction with the direction S to the OPUS system With the option Send to OPUS only on data v...

Page 21: ...he OPUS system Only if these two values differ an EIB KNX ValueWrite with the reveived data value is transmit ted to the EIB KNX bussystem This means if you send 3 times the OPUS instruction 11S0105 y...

Page 22: ...Rev 04 2012 KNX OPUS Gateway Page 22 of 25 b b Automations und Steuerungstechnik GmbH KNX OPUS GATEWAY DOC Figure 20 Parametrisation dialog b b KNX OPUS Gateway Online...

Page 23: ...ation phase If the KNX OPUS Gateway is running in parametrisation mode the LEDs Error KNX and PGM are blinking altogether Frequency 1Hz Parametrisation check After the system startup the KNX OPUS Gate...

Page 24: ...a short overview of all ASCII commands if you send the command or H to the KNX OPUS Gateway H Show ASCII command overview V Show information about serial number and firmware version ot the KNX OPUS Ga...

Page 25: ...ay Page 25 of 25 b b Automations und Steuerungstechnik GmbH KNX OPUS GATEWAY DOC OLE Language of dialog texts English PA PA Set physical address PA e g PA 1 1 254 RESET Restart KNX OPUS Gateway Table...

Reviews: