Monitor the green LED labeled OK on the craft interface corresponding to the slot as soon as an interface
card is seated in an operating services gateway.
The Routing Engine downloads the interface card’s software to it under two conditions: the interface
card is present when the Routing Engine boots Junos OS, and the interface card is installed and requested
online through the CLI or push button on the front panel. The interface card then runs diagnostics, during
which the OK LED blinks. When the interface card is online and functioning normally, the OK LED lights
green steadily.
•
Make sure the interface card is properly seated in the midplane. Check that each ejector handle has
been turned clockwise and is tight.
•
Check the OK/FAIL LED on the interface card and OK and FAIL LEDs for the slot on the craft interface.
When the interface card is online and functioning normally, the OK LED lights green steadily.
•
Issue the CLI show chassis fpc command to check the status of installed interface cards. As shown in
the sample output, the value Online in the column labeled State indicates that the interface card is
functioning normally:
user@host>
show chassis fpc
Temp CPU Utilization (%) Memory Utilization (%)
Slot State (C) Total Interrupt DRAM (MB) Heap Buffer
0 Online 41 9 0 1024 15 57
1 Online 43 5 0 1024 16 57
2 Online 43 11 0 1024 16 57
3 Empty
4 Empty
5 Online 42 6 0 1024 16 57
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host>
show chassis fpc detail
Slot 0 information:
State Online
Temperature 41 degrees C / 105 degrees F
Total CPU DRAM 1024 MB
Total RLDRAM 256 MB
Total DDR DRAM 4096 MB
Start time: 2007-07-10 12:28:33 PDT
Uptime: 1 hour, 33 minutes, 52 seconds
Slot 1 information:
State Online
446
Summary of Contents for SRX 5800
Page 1: ...SRX5800 Services Gateway Hardware Guide Published 2020 02 10 ...
Page 23: ......
Page 30: ...Figure 2 Rear View of a Fully Configured AC Powered Services Gateway Chassis 31 ...
Page 111: ...LEDs 112 ...
Page 121: ...Port and Interface Numbering 122 ...
Page 127: ...Port and Interface Numbering 128 ...
Page 161: ......
Page 179: ... One SRX5K MPC IOC2 Modular Port Concentrator with two Modular Interface Cards MICs 180 ...
Page 180: ... One SRX5K 40GE SFP I O card IOC 181 ...
Page 205: ......
Page 261: ......
Page 324: ...c Upload the configuration to RE2 from the USB device 325 ...
Page 365: ...Figure 143 Installing an SPC 366 ...
Page 367: ...368 ...
Page 422: ...5 CHAPTER Troubleshooting Hardware Troubleshooting the SRX5800 425 ...
Page 423: ......
Page 457: ......
Page 473: ...475 ...
Page 476: ...Restricted Access Area Warning 478 ...
Page 483: ...485 ...
Page 496: ...Jewelry Removal Warning 498 ...
Page 499: ...Operating Temperature Warning 501 ...
Page 509: ...DC Power Disconnection Warning 511 ...
Page 513: ...DC Power Wiring Sequence Warning 515 ...
Page 516: ...DC Power Wiring Terminations Warning 518 ...
Page 519: ...DC Power Disconnection Warning 521 ...
Page 523: ...DC Power Wiring Sequence Warning 525 ...